This interface defines a logical serial port connection. A "logical" serial port is defined as a logical connection through which bytes are transferring serially. The logical serial port is defined within the underlying operating system and may not necessarily correspond to a physical RS-232 serial port. For instance, IrDA IRCOMM ports can commonly be configured as a logical serial port within the operating system so that it can act as a "logical" serial port.
A comm port is accessed using a Generic Connection Framework string with an explicit port identifier and embedded configuration parameters, each separated with a semi-colon (;).
Only one application may be connected to a particular serial port at a
given time.
An java.io.IOException
is thrown, if an attempt is
made to open the serial port with Connector.open()
and the connection is already open.
A URI with the type and parameters is used to open the connection.
The scheme (defined in RFC 2396) must be:
comm:<port identifier>[<optional parameters>]
The first parameter must be a port identifier, which is a logical device name. These identifiers are most likely device specific and should be used with care.
The valid identifiers for a particular device and OS can be queried through
the method System.getProperty()
using the key
"microedition.commports". A comma separated list of ports
is returned which can be combined with a comm:
prefix
as the URL string to be used to open a serial port connection.
(See port naming convention below.)
Any additional parameters must be separated by a semi-colon (;) and spaces are not allowed in the string. If a particular optional parameter is not applicable to a particular port, the parameter MAY be ignored. The port identifier MUST NOT contain a semi-colon (;).
Legal parameters are defined by the definition of the parameters below.
Illegal or unrecognized parameters cause an IllegalArgumentException
.
If the value of a parameter is supported by the device,
it must be honored. If the value of a parameter is not supported
a java.io.IOException
is thrown.
If a baudrate
parameter is requested, it is treated
in the same way that the setBaudRate
method
handles baudrates. e.g., if the baudrate requested is not
supported the system MAY substitute a valid baudrate, which
can be discovered using the getBaudRate
method.
Parameter | Default | Description |
---|---|---|
baudrate |
platform dependent |
The speed of the port. |
bitsperchar |
8 |
The number bits per character(7 or 8 ). |
stopbits |
1 |
The number of stop bits per char(1 or 2 ) |
parity |
none |
The parity can be odd , even ,
or none . |
blocking |
on |
If on , wait for a full buffer when reading. |
autocts |
on |
If on , wait for the CTS line to be on
before writing. |
autorts |
on |
If on , turn on the RTS line when the
input buffer is not full. If off ,
the RTS line is always on. |
The URI must conform to the BNF syntax specified below. If the URI
does not conform to this syntax, an IllegalArgumentException
is thrown.
<comm_connection_string> | ::= "comm:"<port_id>[<options_list>] ; |
<port_id> | ::= string of alphanumeric characters |
<options_list> | ::= *(<baud_rate_string>| <bitsperchar>|
<stopbits>| <parity>|
<blocking>| <autocts>|
<autorts>) ;
; if an option duplicates a previous option in the ; option list, that option overrides the previous ; option |
<baud_rate_string> | ::= ";baudrate="<baud_rate> |
<baud_rate> | ::= string of digits |
<bitsperchar> | ::= ";bitsperchar="<bit_value> |
<bit_value> | ::= "7" | "8" |
<stopbits> | ::= ";stopbits="<stop_value> |
<stop_value> | ::= "1" | "2" |
<parity> | ::= ";parity="<parity_value> |
<parity_value> | ::= "even" | "odd" | "none" |
<blocking> | ::= ";blocking="<on_off> |
<autocts> | ::= ";autocts="<on_off> |
<autorts> | ::= ";autorts="<on_off> |
<on_off> | ::= "on" | "off" |
Access to serial ports is restricted to prevent unauthorized
transmission or reception of data. The security model applied to
the serial port connection is defined in the implementing profile.
The security model may be applied on the invocation of the
Connector.open()
method with a valid serial port connection string.
Should the application
not be granted access to the serial port through the profile
authorization scheme, a
java.lang.SecurityException
will be thrown from the
Connector.open()
method.
The security model MAY also be applied during execution, specifically
when the methods
openInputStream()
, openDataInputStream()
,
openOutputStream()
, and
openDataOutputStream()
are invoked.
The following example shows how a CommConnection
would be used to access a simple loopback program.
CommConnection cc = (CommConnection) Connector.open("comm:com0;baudrate=19200"); int baudrate = cc.getBaudRate(); InputStream is = cc.openInputStream(); OutputStream os = cc.openOutputStream(); int ch = 0; while(ch != 'Z') { os.write(ch); ch = is.read(); ch++; } is.close(); os.close(); cc.close();
The following example shows how a CommConnection
would be used to discover available comm ports.
String port1; String ports = System.getProperty("microedition.commports"); int comma = ports.indexOf(','); if (comma > 0) { // Parse the first port from the available ports list. port1 = ports.substring(0, comma); } else { // Only one serial port available. port1 =ports; }
Logical port names can be defined to match platform naming conventions
using any combination of alphanumeric characters. However, it is
recommended that ports be named consistently among the implementations
of this class according to a proposed convention. VM implementations
should follow the following convention:
Port names contain a text abbreviation indicating port capabilities followed
by a sequential number for the port. The following device name types should
be used:
This naming scheme allows API users to generally determine the type of port that they would like to use. For instance, if a application desires to "beam" a piece of data, the app could look for "IR#" ports for opening the connection. The alternative is a trial and error approach with all available ports.
Method Summary | |
int |
getBaudRate()
Gets the baudrate for the serial port connection. |
int |
setBaudRate(int baudrate)
Sets the baudrate for the serial port connection. |
Methods inherited from interface javax.microedition.io.InputConnection |
openDataInputStream, openInputStream |
Methods inherited from interface javax.microedition.io.Connection |
close |
Methods inherited from interface javax.microedition.io.OutputConnection |
openDataOutputStream, openOutputStream |
Method Detail |
public int getBaudRate()
setBaudRate(int)
public int setBaudRate(int baudrate)
baudrate
is not supported
on the platform, then the system MAY use an alternate valid setting.
The alternate value can be accessed using the
getBaudRate
method.
baudrate
- the baudrate for the connection
getBaudRate()
|