MID Profile | ||||||||||
PREV CLASS NEXT CLASS | FRAMES NO FRAMES | ||||||||||
SUMMARY: NESTED | FIELD | CONSTR | METHOD | DETAIL: FIELD | CONSTR | METHOD |
java.lang.Object javax.microedition.lcdui.Item javax.microedition.lcdui.Gauge
Implements a graphical display, such as a bar graph, of an integer
value. The Gauge
contains a current value
that lies between zero and the maximum value, inclusive.
The application can control the current value and maximum value.
The range of values specified by the application may be larger than
the number of distinct visual states possible on the device, so
more than one value may have the same visual representation.
For example, consider a Gauge
object that has a
range of values from zero to 99
, running on a device
that displays the Gauge's
approximate value using a
set of one to ten bars. The device might show one bar for values
zero through nine, two bars for values ten through 19
,
three bars for values 20
through 29
, and
so forth.
A Gauge
may be interactive or
non-interactive. Applications may set or retrieve the
Gauge's
value at any time regardless of the
interaction mode. The implementation may change the visual
appearance of the bar graph depending on whether the object is
created in interactive mode.
In interactive mode, the user is allowed to modify the value. The user will always have the means to change the value up or down by one and may also have the means to change the value in greater increments. The user is prohibited from moving the value outside the established range. The expected behavior is that the application sets the initial value and then allows the user to modify the value thereafter. However, the application is not prohibited from modifying the value even while the user is interacting with it.
In many cases the only means for the user to modify the value will be to press a button to increase or decrease the value by one unit at a time. Therefore, applications should specify a range of no more than a few dozen values.
In non-interactive mode, the user is prohibited from modifying
the value. Non-interactive mode is used to provide feedback to the
user on the state of a long-running operation. One expected use of
the non-interactive mode is as a "progress indicator" or
"activity indicator" to give the user some feedback
during a long-running operation. The application may update the
value periodically using the setValue()
method.
A non-interactive Gauge
can have a definite or
indefinite range. If a Gauge
has definite range, it
will have an integer value between zero and the maximum value set
by the application, inclusive. The implementation will provide a
graphical representation of this value such as described above.
A non-interactive Gauge
that has indefinite range
will exist in one of four states: continuous-idle,
incremental-idle, continuous-running, or incremental-updating.
These states are intended to indicate to the user that some level
of activity is occurring. With incremental-updating, progress can
be indicated to the user even though there is no known endpoint to
the activity. With continuous-running, there is no progress that
gets reported to the user and there is no known endpoint;
continuous-running is merely a busy state indicator. The
implementation should use a graphical display that shows this
appropriately. The implementation may use different graphics for
indefinite continuous gauges and indefinite incremental gauges.
Because of this, separate idle states exist for each mode. For
example, the implementation might show an hourglass or spinning
watch in the continuous-running state, but show an animation with
different states, like a beach ball or candy-striped bar, in the
incremental-updating state.
In the continuous-idle or incremental-idle state, the
Gauge
indicates that no activity is occurring. In the
incremental-updating state, the Gauge
indicates
activity, but its graphical representation should be updated only
when the application requests an update with a call to
setValue()
. In the continuous-running state, the
Gauge
indicates activity by showing an animation that
runs continuously, without update requests from the
application.
The values CONTINUOUS_IDLE
,
INCREMENTAL_IDLE
, CONTINUOUS_RUNNING
, and
INCREMENTAL_UPDATING
have their special meaning only
when the Gauge
is non-interactive and has been set to
have indefinite range. They are treated as ordinary values if the
Gauge
is interactive or if it has been set to have a
definite range.
An application using the Gauge
as a progress
indicator should typically also attach a STOP
command to the container containing the Gauge
to allow
the user to halt the operation in progress.
As mentioned above, a non-interactive Gauge
may be
used to give user feedback during a long-running operation. If the
application can observe the progress of the operation as it
proceeds to an endpoint known in advance, then the application
should use a non-interactive Gauge
with a definite
range. For example, consider an application that is downloading a
file known to be 20
kilobytes in size. The
application could set the Gauge's
maximum value to be
20
and set its value to the number of kilobytes
downloaded so far. The user will be presented with a
Gauge
that shows the portion of the task completed at
any given time.
If, on the other hand, the application is downloading a file of
unknown size, it should use a non-interactive Gauge
with indefinite range. Ideally, the application should call
setValue(INCREMENTAL_UPDATING)
periodically, perhaps
each time its input buffer has filled. This will give the user an
indication of the rate at which progress is occurring.
Finally, if the application is performing an operation but has
no means of detecting progress, it should set a non-interactive
Gauge
to have indefinite range and set its value to
CONTINUOUS_RUNNING
or CONTINUOUS_IDLE
as
appropriate. For example, if the application has issued a request
to a network server and is about to block waiting for the server to
respond, it should set the Gauge's
state to
CONTINUOUS_RUNNING
before awaiting the response, and it
should set the state to CONTINUOUS_IDLE
after it has
received the response.
Field Summary | |
static int |
CONTINUOUS_IDLE
The value representing the continuous-idle state of a non-interactive Gauge with indefinite range. |
static int |
CONTINUOUS_RUNNING
The value representing the continuous-running state of a non-interactive Gauge with indefinite range. |
static int |
INCREMENTAL_IDLE
The value representing the incremental-idle state of a non-interactive Gauge with indefinite range. |
static int |
INCREMENTAL_UPDATING
The value representing the incremental-updating state of a non-interactive Gauge with indefinite range. |
static int |
INDEFINITE
A special value used for the maximum value in order to indicate that the Gauge has indefinite range. |
Fields inherited from class javax.microedition.lcdui.Item |
BUTTON, HYPERLINK, LAYOUT_2, LAYOUT_BOTTOM, LAYOUT_CENTER, LAYOUT_DEFAULT, LAYOUT_EXPAND, LAYOUT_LEFT, LAYOUT_NEWLINE_AFTER, LAYOUT_NEWLINE_BEFORE, LAYOUT_RIGHT, LAYOUT_SHRINK, LAYOUT_TOP, LAYOUT_VCENTER, LAYOUT_VEXPAND, LAYOUT_VSHRINK, PLAIN |
Constructor Summary | |
Gauge(String label,
boolean interactive,
int maxValue,
int initialValue)
Creates a new Gauge object with the given
label, in interactive or non-interactive mode, with the given
maximum and initial values. |
Method Summary | |
void |
addCommand(Command cmd)
Adds a context sensitive Command to the item. |
int |
getMaxValue()
Gets the maximum value of this Gauge object. |
int |
getValue()
Gets the current value of this Gauge object. |
boolean |
isInteractive()
Tells whether the user is allowed to change the value of the Gauge . |
void |
setDefaultCommand(Command cmd)
Sets default Command for this Item . |
void |
setItemCommandListener(ItemCommandListener l)
Sets a listener for Commands to this Item,
replacing any previous
ItemCommandListener . |
void |
setLabel(String label)
Sets the label of the Item . |
void |
setLayout(int layout)
Sets the layout directives for this item. |
void |
setMaxValue(int maxValue)
Sets the maximum value of this Gauge object. |
void |
setPreferredSize(int width,
int height)
Sets the preferred width and height for this Item . |
void |
setValue(int value)
Sets the current value of this Gauge object. |
Methods inherited from class javax.microedition.lcdui.Item |
getLabel, getLayout, getMinimumHeight, getMinimumWidth, getPreferredHeight, getPreferredWidth, notifyStateChanged, removeCommand |
Methods inherited from class java.lang.Object |
equals, getClass, hashCode, notify, notifyAll, toString, wait, wait, wait |
Field Detail |
public static final int INDEFINITE
Gauge
has indefinite range. This value may be
used as the maxValue
parameter to the constructor, the parameter passed to
setMaxValue()
, and
as the return value of getMaxValue()
.
The value of INDEFINITE
is -1
.
public static final int CONTINUOUS_IDLE
Gauge
with indefinite range. In
the continuous-idle state, the gauge shows a graphic
indicating that no work is in progress.
This value has special meaning only for non-interactive gauges with indefinite range. It is treated as an ordinary value for interactive gauges and for non-interactive gauges with definite range.
The value of CONTINUOUS_IDLE
is
0
.
public static final int INCREMENTAL_IDLE
Gauge
with indefinite range. In
the incremental-idle state, the gauge shows a graphic
indicating that no work is in progress.
This value has special meaning only for non-interactive gauges with indefinite range. It is treated as an ordinary value for interactive gauges and for non-interactive gauges with definite range.
The value of INCREMENTAL_IDLE
is
1
.
public static final int CONTINUOUS_RUNNING
Gauge
with indefinite range. In
the continuous-running state, the gauge shows a
continually-updating animation sequence that indicates that
work is in progress. Once the application sets a gauge into
the continuous-running state, the animation should proceed
without further requests from the application.
This value has special meaning only for non-interactive gauges with indefinite range. It is treated as an ordinary value for interactive gauges and for non-interactive gauges with definite range.
The value of CONTINUOUS_RUNNING
is
2
.
public static final int INCREMENTAL_UPDATING
Gauge
with indefinite range. In
the incremental-updating state, the gauge shows a graphic
indicating that work is in progress, typically one frame of an
animation sequence. The graphic should be updated to the next
frame in the sequence only when the application calls
setValue(INCREMENTAL_UPDATING)
.
This value has special meaning only for non-interactive gauges with indefinite range. It is treated as an ordinary value for interactive gauges and for non-interactive gauges with definite range.
The value of INCREMENTAL_UPDATING
is
3
.
Constructor Detail |
public Gauge(String label, boolean interactive, int maxValue, int initialValue)
Gauge
object with the given
label, in interactive or non-interactive mode, with the given
maximum and initial values. In interactive mode (where
interactive
is true
) the maximum
value must be greater than zero, otherwise an exception is
thrown. In non-interactive mode (where
interactive
is false
) the maximum
value must be greater than zero or equal to the special value
INDEFINITE
, otherwise an exception is thrown.
If the maximum value is greater than zero, the gauge has
definite range. In this case the initial value must be within
the range zero to maxValue
, inclusive. If the
initial value is less than zero, the value is set to zero. If
the initial value is greater than maxValue
, it is
set to maxValue
.
If interactive
is false
and the
maximum value is INDEFINITE
, this creates a
non-interactive gauge with indefinite range. The initial value
must be one of CONTINUOUS_IDLE
,
INCREMENTAL_IDLE
, CONTINUOUS_RUNNING
,
or INCREMENTAL_UPDATING
.
label
- the Gauge's
labelinteractive
- tells whether the user can change the valuemaxValue
- the maximum value, or INDEFINITE
initialValue
- the initial value in the range
[0..maxValue]
, or one of CONTINUOUS_IDLE
,
INCREMENTAL_IDLE
, CONTINUOUS_RUNNING
,
or INCREMENTAL_UPDATING
if maxValue
is
INDEFINITE
.
IllegalArgumentException
- if maxValue
is not positive for interactive gauges
IllegalArgumentException
- if maxValue
is
neither positive nor
INDEFINITE
for non-interactive gauges
IllegalArgumentException
- if initialValue is not one of
CONTINUOUS_IDLE
, INCREMENTAL_IDLE
,
CONTINUOUS_RUNNING
, or INCREMENTAL_UPDATING
for a non-interactive gauge with indefinite rangeINDEFINITE
,
CONTINUOUS_IDLE
,
INCREMENTAL_IDLE
,
CONTINUOUS_RUNNING
,
INCREMENTAL_UPDATING
Method Detail |
public void setLabel(String label)
Item
. If label
is null
, specifies that this item has no label.
It is illegal to call this method if this Item
is contained within an Alert
.
setLabel
in class Item
label
- the label string
IllegalStateException
- if this Item
is contained
within an Alert
Item.getLabel()
public void setLayout(int layout)
It is illegal to call this method if this Item
is contained within an Alert
.
setLayout
in class Item
layout
- a combination of layout directive values for this item
IllegalArgumentException
- if the value of layout is not a valid
combination of layout directives
IllegalStateException
- if this Item
is
contained within an Alert
Item.getLayout()
public void addCommand(Command cmd)
Command
to the item.
The semantic type of
Command
should be ITEM
. The implementation
will present the command
only when the the item is active, for example, highlighted.
If the added command is already in the item (tested by comparing the object references), the method has no effect. If the item is actually visible on the display, and this call affects the set of visible commands, the implementation should update the display as soon as it is feasible to do so.
It is illegal to call this method if this Item
is contained within an Alert
.
addCommand
in class Item
cmd
- the command to be added
IllegalStateException
- if this Item
is contained
within an Alert
NullPointerException
- if cmd is null
public void setItemCommandListener(ItemCommandListener l)
Commands
to this Item,
replacing any previous
ItemCommandListener
. A null
reference
is allowed and has the effect of
removing any existing listener.
It is illegal to call this method if this Item
is contained within an Alert
.
setItemCommandListener
in class Item
l
- the new listener, or null
.
IllegalStateException
- if this Item
is contained
within an Alert
public void setPreferredSize(int width, int height)
Item
.
Values for width and height less than -1
are illegal.
If the width is between zero and the minimum width, inclusive,
the minimum width is used instead.
If the height is between zero and the minimum height, inclusive,
the minimum height is used instead.
Supplying a width or height value greater than the minimum width or
height locks that dimension to the supplied
value. The implementation may silently enforce a maximum dimension for
an Item
based on factors such as the screen size.
Supplying a value of
-1
for the width or height unlocks that dimension.
See Item Sizes for a complete discussion.
It is illegal to call this method if this Item
is contained within an Alert
.
setPreferredSize
in class Item
width
- the value to which the width should be locked, or
-1
to unlockheight
- the value to which the height should be locked, or
-1
to unlock
IllegalArgumentException
- if width or height is less than
-1
IllegalStateException
- if this Item
is contained
within an Alert
Item.getPreferredHeight()
,
Item.getPreferredWidth()
public void setDefaultCommand(Command cmd)
Command
for this Item
.
If the Item
previously had a
default Command
, that Command
is no longer the default, but it
remains present on the Item
.
If not null
, the Command
object
passed becomes the default Command
for this Item
. If the Command
object
passed is not currently present
on this Item
, it is added as if addCommand(javax.microedition.lcdui.Command)
had been called
before it is made the default Command
.
If null
is passed, the Item
is set to
have no default Command
.
The previous default Command
, if any, remains present
on the Item
.
It is illegal to call this method if this Item
is contained within an Alert
.
setDefaultCommand
in class Item
cmd
- the command to be used as this Item's
default
Command
, or null
if there is to
be no default command
IllegalStateException
- if this Item
is contained
within an Alert
public void setValue(int value)
Gauge
object.
If the gauge is interactive, or if it is non-interactive with definite range, the following rules apply. If the value is less than zero, zero is used. If the current value is greater than the maximum value, the current value is set to be equal to the maximum value.
If this Gauge
object is a non-interactive
gauge with indefinite
range, then value must be one of CONTINUOUS_IDLE
,
INCREMENTAL_IDLE
, CONTINUOUS_RUNNING
, or
INCREMENTAL_UPDATING
.
Other values will cause an exception to be thrown.
value
- the new value
IllegalArgumentException
- if value is not one of
CONTINUOUS_IDLE
, INCREMENTAL_IDLE
,
CONTINUOUS_RUNNING
, or INCREMENTAL_UPDATING
for non-interactive gauges with indefinite rangeCONTINUOUS_IDLE
,
INCREMENTAL_IDLE
,
CONTINUOUS_RUNNING
,
INCREMENTAL_UPDATING
,
getValue()
public int getValue()
Gauge
object.
If this Gauge
object is a non-interactive
gauge with indefinite
range, the value returned will be one of CONTINUOUS_IDLE
,
INCREMENTAL_IDLE
, CONTINUOUS_RUNNING
, or
INCREMENTAL_UPDATING
. Otherwise, it will be an integer
between zero and the gauge's maximum value, inclusive.
Gauge
CONTINUOUS_IDLE
,
INCREMENTAL_IDLE
,
CONTINUOUS_RUNNING
,
INCREMENTAL_UPDATING
,
setValue(int)
public void setMaxValue(int maxValue)
Gauge
object.
For interactive gauges, the new maximum value must be greater than
zero, otherwise an exception is thrown. For non-interactive gauges,
the new maximum value must be greater than zero or equal to the special
value INDEFINITE
, otherwise an exception is thrown.
If the new maximum value is greater than zero, this provides the gauge with a definite range. If the gauge previously had a definite range, and if the current value is greater than new maximum value, the current value is set to be equal to the new maximum value. If the gauge previously had a definite range, and if the current value is less than or equal to the new maximum value, the current value is left unchanged.
If the new maximum value is greater than zero, and if the gauge had
previously had indefinite range, this new maximum value provides it
with a definite range. Its graphical representation must change
accordingly, the previous state of CONTINUOUS_IDLE
,
INCREMENTAL_IDLE
, CONTINUOUS_RUNNING
, or
INCREMENTAL_UPDATING
is ignored, and the current value
is set to zero.
If this gauge is non-interactive and the new maximum value is
INDEFINITE
, this gives the gauge indefinite range.
If the gauge
previously had a definite range, its graphical representation must
change accordingly, the previous value is ignored, and the current
state is set to CONTINUOUS_IDLE
. If the gauge previously
had an indefinite range, setting the maximum value to
INDEFINITE
will have no effect.
maxValue
- the new maximum value
IllegalArgumentException
- if maxValue
is invalidINDEFINITE
,
getMaxValue()
public int getMaxValue()
Gauge
object.
If this gauge is interactive, the maximum value will be a positive
integer. If this gauge is non-interactive, the maximum value will be a
positive integer (indicating that the gauge has definite range)
or the special value INDEFINITE
(indicating that
the gauge has
indefinite range).
Gauge
, or
INDEFINITE
INDEFINITE
,
setMaxValue(int)
public boolean isInteractive()
Gauge
.
Gauge
is
interactive
|
MID Profile | ||||||||||
PREV CLASS NEXT CLASS | FRAMES NO FRAMES | ||||||||||
SUMMARY: NESTED | FIELD | CONSTR | METHOD | DETAIL: FIELD | CONSTR | METHOD |